1/4 SAE Straight female fitting
![]() |
|||
Part no. | XIA02M | WIA02M | KIA02M |
Pack |
50 pcs
|
50 pcs
|
10 pcs
|
Copper gasket | ![]() |
![]() |
![]() |
1/4 SAE Elbow female 90° fitting^ to top
![]() |
|||
Part no. | XJA02M | WJA02M | KJA02M |
Pack |
50 pcs
|
50 pcs
|
10 pcs
|
Copper gasket | ![]() |
![]() |
![]() |
Assembly instructions for reusable fittings^ to top
1
|
Cut QUADRA DN4 capillary hose to the required length using our cutter for capillary hoses type WXA004. |
2
|
Push the ferrule over the hose end you want to assemble. To make the operation easier we advise that you lubricate the components with refrigeration oil. |
3
|
Screw counter clockwise, by hand, the first turns of the thread of the ferrule. A suitable wrench screw counter clockwise until the ferrule is in line with the hose. |
4
|
Place the insert into the hose end you want to assemble. To make the operation easier we advise that you lubricate the components with refrigeration oil. |
5
|
Screw clockwise, by hand, the first turns of the thread of the insert into the ferrule previously fitted on the hose. Screw clockwise the fitting into the ferrule until they are in line with each other by using a wrench and a counter wrench. |
6
|
After checking the correct positioning of the components, the assembling is finished. |